Some differences may exist between french and english regulations. Lessons learned are only a translation of those of french incident and are not adapt to english regulation.

pdf Irradiation of three people during maintenance of an accelerator (89 kB)

Description of incident

The incident occurred in an ionization treatment facility. This facility, which was operated by four people (two operators qualified to use the device, and two handlers), housed an electron accelerator emitting a beam of a maximum intensity of 100 mA at a maximum acceleration voltage of 800 kV.

The operation of the machine is controlled by a four position switch:

  • “Off”;
  • “Control” (allows the use of ancillary equipment without operating the accelerator: i.e. conveyor belt, ventilation system, cooling circuit);
  • “Acceleration voltage”; and
  • “Electron voltage and source”.

The incident occurred when three agents deliberately locked themselves inside the irradiation room in order to verify the functioning of the ventilation system. They suspected a failure of the system because of adhesion problems between the conveyor belt (used to pass the products under the beam) and the irradiated products, as well as the presence of some suspicious deposits on the walls and floor of the facility. To start the ventilation while remaining inside, the “control rounds” procedure was instigated. This procedure consisted of operating (using the key that closes the access door) four locks placed in different positions, in order to verify that no person is present.

The operator, who remained at the command post and who was to set the machine to “control” mode to start the ventilation system, accidentally triggered the device start up which caused the activation, in standby mode, of the electron source (a heated tungsten filament). In this mode, the electron source is hidden by a shield that stops a significant fraction of the radiation and which is activated by the non-conveyance of the belt.

A few minutes later, one of the operators inside the room detected a bluish glimmer (a sign of the presence of electrons) and heard a suspicious noise; he immediately signaled his two colleagues to evacuate the room, which was done in a few seconds.

Radiological consequences

The operators in this facility were not wearing personal dosemeters.

The doses received were estimated from a dosimetric reconstruction of the accident which involved the following actions:

  • Reconstruction of the path the persons took during the various stages of the accident. This included the routes taken, their specific actions, and the time they were present at the various internal locations. The persons were estimated to be inside the room for five and a half minutes, whereas the electron beam production time was estimated at three minutes.
  • Placement of dosimeters, at the various points where the persons were stood, on supports at 1.3 meters from the ground in order to represent the normal conditions of dosimeter wear (chest) (an exposure to the chest was considered as representative of a whole body exposure).
  • Repeating the start-up sequence of the accelerator, from the command post, reproducing what had been done the day of accident.
  • Addition of measured doses in proportion to the individual operators’ time at each location.

The effective doses received by each person were evaluated at between 30 and 35 mSv.

Lessons to be learned from the incident

Clear warning signals must be installed to indicate when an exposure is about to take place, and separate signals should indicate when an exposure is taking place. The pre-warning signals must be sufficient to allow persons inside to either escape or terminate the exposure before it starts. It is also recommended that a separate radiation detection system be installed inside the room.

During this incident, an appropriate monitor would have immediately informed the parties involved of the presence of radiation, and would have facilitated the evacuation and reduced the doses received.

It is essential to provide personnel with suitable information and training at regular intervals - the two operators had actually received training when they were recruited, but this training had not been reviewed or refreshed; the two handlers had no training. In addition to the general rules for radiation protection, the training must include specific rules applicable to the facility.

The persons involved must never, under penalty of disciplinary sanction, override or by-pass any safety systems or procedures, even if it is necessary to carry out repairs on the ancillary equipment (ventilation system, cooling circuit, etc.).

Any special procedures requiring entry into the facility must be done in the presence of a qualified person in charge of radiation protection, who should assist in preparing detailed instructions on the accelerator’s mode of operation.